AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer

AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer

  • AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
  • AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
  • AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
  • AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
  • AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
  • AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer
รายละเอียดสินค้า:
ชื่อแบรนด์: PG instruments
ได้รับการรับรอง: CE
Model Number: AF402
การชำระเงิน:
Minimum Order Quantity: 1 unit
ราคา: Contact for a quote
Packaging Details: Carton package, 1280x800x800mm, 100kg
Delivery Time: Contact for confirmation
Payment Terms: T/T,L/C
Supply Ability: 500 units per year
ติดต่อ
รายละเอียดสินค้า
แสงสูง:

Atomic Fluorescence Spectrometer

,

Atomic Absorption Spectrophotometer

 

 

AF402 Adjustable Height Elemental Analyzers, Atomic Fluorescence Spectrometer

  

 

Detection  Limit

Element

Detection Limit (ug/L)

RSD (%)

As, Se, Pb, Bi, Te, Sn, Sb

< 0.01

< 1.0

Hg, Cd

< 0.001

< 1.0

Zn

< 1.0

< 1.0

Ge

< 0.05

< 1.0

 

Applications:

Agricultural

Food and Beverage

Public Health

Clinical

Pharmaceutical 

Geological 

Metallurgical 

Petrochemical 

 

 

Specifications:

 

Sample Automisation

Atomizer

Quartz tube furnace with auto ignition of argon/hydrogen flame

Furnace heating

Computer controlled heating

Hydride generator 

Continuous flow high performance for cold-vapour mercury and hydride

determinations of As, Se, Te, Bi, Sb, Sn, Zn, Pb, Cd, Ge

Gas requirement

High purity argon gas (99.99%) 30psi pressure

Sample and Delivery

Peristaltic pump

3 channel pump with 3 adjustable pressure control clamps and

programmable speed control

Exhaust system

Built in with filter to decontaminate pollutants

Gas/liquid separator

High efficiency two-stage gas-liquid separator

Autosampler

Type 

XYZ built in design

Sample introduction

High sample capacity, automated introduction of sample and standards

 by motorized syringe drive

Sample capacity

2 x45 standard test tube sample racks

Optics 

Optical design

Short focal length, non-dispersive integrated optical design

Light source

3 channel simultaneous element analysis using computer controlled. 

Modulated and pulsed, hollow cathode light source

Baseline stability

<2%

Linear range

>10

Computer System

Operating software

PF Win software

Safety

Alarm for low gas <50ml/min. Gas cut off in the event of power 

supply loss

Power requirements

220Vac+10% 50/60hz 300W

Dimensions 

100.6x58x55cm

 

 

The Atomic Fluorescence Spectroscopy (AFS) technique is widely used for determination of hydride forming elements and Mercury analysis. The technique provides an alternative to the conventional method of connecting a hydride generator to an Atomic Absorption Spectrophotometer (AAS). Due to the high intensity Hollow Cathode lamp source and low baseline noise offered by this technique, the usable sensitivity is greatly improved offering very low detection limits (ppt).

The AFS instrument fulfils the analysis by means of simultaneous detection, accurate sample introduction and stable furnace temperature control complementing the more widely used AAS flame/graphite systems.


 

Standard Features

Light Source

  • High intensity Hollow Cathode lamps for greater intensity and stability

  • Up to three lamps can be installed for simultaneous analysis

  • All lamps are uniquely data coded offering important information to the PF Win operating software

  • Optical System

  • Shielded optical design greatly reduces light interference

  • Enhanced signal to noise ratio for increased analytical sensitivity

  • Unique optical configuration for increased fluorescence intensity. Up to twice the fluorescence intensity found in traditional AFS systems.

  • High Quantum Solar Blind Photomultiplier Tube fitted as standard to ensure optimum stability
     

Atomiser System

  • High precision quartz atomizer tube designed for optimum performance, durability and long life
  • Self-igniting Argon/Hydrogen flame with software controlled heater coil

  • Adjustable height control for improved optimization

  • Integrated fume exhaust system to decontaminate pollution
     

Hydride Generator

  • Built in hydride generator with continuous flow
  • Multi-pump with individual pressure adjustment for uptake control of reagents and carrier liquids

  • Introduction of sample using motorized syringe drive and unique three way control valve. Software controlled for greater accuracy

  • High efficiency glass liquid separator which optimizes the separation minimizing pressure fluctuations and improving measurement precision

  • Reagent compartment stores reagents safely and cleanly. Storage for up to four containers

  • Low level reagent monitoring
     


Autosampler

 

  •  Integrated autosampler
  •  XYZ configuration
  •  x 45 vial trays for automated sample introduction
  •  Auto dilution using motorized syringe drive and selection valve
  •  Full calibration using only one stock standard solution
  •  Fully controlled by the PF Win software
  •  Electronic Control System
  •  High technology electronics and PCB components
  • Rear mounted and separated electronic section to eliminate carry over from hydride technique
  • PF Win instrument control software
     

 

 